Usage Overview
<p>[TOC]</p>
<h3>I. Summary Description</h3>
<p>Passenger flow statistics: according to the algorithm, control the IO port to open and close the door, and through the passenger flow camera to count the number of people getting on and off the bus.</p>
<h3>II. Conditions of use</h3>
<p>1, the device supports the statistical calculation method of passenger flow.
2, the enable of IO port opposite to the algorithm is close.
3, connect the corresponding passenger flow camera.
4, The device and the software are in the same network/network segment, if the device does not support wired, WIFI (AP mode) can be used and the client connects to this WIFI.</p>
<h3>III. Process guidelines</h3>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=fc460e636b6bd8bcfc31950d6ae4aa83" alt="" /></p>
<h4>- Function Verification</h4>
<p>For example: IO1 is set to high level to open the door.
1, IO1 access to 12V voltage.
2, walk back and forth in the passenger flow statistics camera to ensure that the portrait in the camera range.
3, IO1 disconnect voltage, check whether the number of software opening and closing the door statistics normal.
4, At the CMSV6-Reports- Passenger RPT to see whether the passenger flow statistics report can be queried.</p>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=53cb48d5c33c45cd6e9a1881e19114e8" alt="" /></p>