Audible and visual alarms
<p>[TOC]</p>
<h3>I. Summary Description</h3>
<ol>
<li>Sound and light alarm, applied to dump trucks, buses, buses, trucks, special vehicles outside the car alarm, built-in high-power speakers and bright flashing lights, beautiful structure, easy to install, and dustproof and waterproof.</li>
<li>Mainly used for blind spot alarms and left/right turn alarms.</li>
<li>Supports signal-triggered alarms (5V or above) and 485 serial port-triggered alarms.</li>
</ol>
<table>
<thead>
<tr>
<th style="text-align: center;">Model</th>
<th style="text-align: center;">Introduction</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: center;">Intelligent sound and light alarm</td>
<td style="text-align: center;">[WCH-ALARM-S310B承认书【航空头】.pdf](<a href="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&sign=fd12afc1b433d3f455903b1dfd9d33fd">http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&sign=fd12afc1b433d3f455903b1dfd9d33fd</a> "[WCH-ALARM-S310B承认书【航空头】.pdf")</td>
</tr>
<tr>
<td style="text-align: center;">CRSGA485</td>
<td style="text-align: center;">[科瑞斯特声光报警器CR-SGA100规格书增加音量控制.docx](<a href="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&sign=a03ebee884681c0037abff67c5b8de70">http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&sign=a03ebee884681c0037abff67c5b8de70</a> "[科瑞斯特声光报警器CR-SGA100规格书增加音量控制.docx")</td>
</tr>
</tbody>
</table>
<h3>II. Conditions of use</h3>
<ol>
<li>With audible and visual alarms that support signal triggering, the device needs to support IO outputs.</li>
<li>Audible and visual alarms triggered using serial communication require the use of a sensor model supported by the device.</li>
<li>The sensor is properly wired to the unit.</li>
<li>The parameters of the Serial Port Management page on the device menu are set correctly.</li>
</ol>
<h3>III. Process guidelines</h3>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=676a528418084fa68ce0822eda148310" alt="" /></p>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=c61e0c8e33c4cccc2142f8512faf69f7" alt="" /></p>
<h3>IV. Detailed operation</h3>
<h4>Intelligent sound and light alarm</h4>
<h4>1. sensor information</h4>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=aaf7f94cff1169815b99ae403bafeb1e" alt="" /></p>
<h4>2. wiring</h4>
<ul>
<li>The positive terminal of the audible and visual alarm is connected to the device IO OUT, and the negative terminal is connected to the device GND wire.</li>
<li>If the device has more than one IO OUT, you can select one by yourself.
<img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=c9f0a339b892c09d3d75eace92ae5331" alt="" /></li>
</ul>
<h4>3. Menu setting</h4>
<p><strong>Example: The audible and visual alarms work when the right BSD alarm needs to be triggered.</strong>
Select IO OUT at right BSD alarm in<strong> AI -BSD-LINK SET</strong>.
<img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=a4e519544ab6b265ca95fe8eb8c5b401" alt="" /></p>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=be7d931a9cdf94e09631b8893edd5e69" alt="" /></p>
<h4>4. status display</h4>
<p><strong>Trigger the right BSD alarm to see if the audible and visual alarms are working properly.</strong></p>
<h4>CRSGA485</h4>
<h4>1. sensor information</h4>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=2850c0e18ff11bc5861647132c1624ff" alt="" /></p>
<h4>2. wiring</h4>
<p>1VCC to device 12V-OUT, 2B to device 458-B, 3A to device 485-A, and 4GND to device GND.
<img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=c87ddf92b55242407b0e6395f079758a" alt="" />
<img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=bb0f7dc1a9e8a909274840c86a77ce3e" alt="" /></p>
<h4>3. Menu setting</h4>
<p><strong>In Peripheral Management-Serial Management</strong> Select tire pressure CRSGA485, baud rate select 9600 (1200-19200) , data bit: 8, stop bit: 1, parity bit: none.
<img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=b45aee68f0de4c96723c30d2fd4e26df" alt="" /></p>
<h4>4. status display</h4>
<p>In the system information-peripheral status can query whether the docking status is successful.
<img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=efb887dfd652c836650384f816a88430" alt="" /></p>
<p><strong>After displaying successful docking, the right BSD alarm is triggered and the sound and light alarms work normally.</strong></p>