Forward And Reverse
<p>[TOC]</p>
<h3>I. Summary Description</h3>
<table>
<thead>
<tr>
<th style="text-align: center;">Model</th>
<th style="text-align: center;">Introduction</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: center;">XYK-J04-M18-N54 Forward and reverse Sensor</td>
<td style="text-align: center;">-</td>
</tr>
</tbody>
</table>
<h3>II. Conditions of use</h3>
<p>1、The sensor model to be supported by the device.
2、The sensor is correctly connected to the IO wireof the device.
3、The IO alarm parameters are set correctly.
4、In the device state, check whether the IO status is normally available.</p>
<h3>III. Process guidelines</h3>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=cb6f7e95d6a26ae54620723872585690" alt="" /></p>
<h3>IV. Detailed operation</h3>
<ul>
<li>
<h4>XYK-J04-M18-N54 Forward and reverse Sensor</h4>
</li>
</ul>
<h5>1, Sensor Information</h5>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=2ffce208cc8a426498b85a84bd84cb35" alt="" /></p>
<h5>2, Wiring Mehod</h5>
<p>The red wire connects to 12V power wire, the black + shield connect to GND wire, yellow connect to IO1, white connect to IO2</p>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=f17322a934b1fd9d31431106b6338958" alt="" /></p>
<h5>3, Menu Setup</h5>
<p>At the <strong>ALARM SETUP-IO</strong>, Set the corresponding forward/reverse/stop rotation.
<strong>Explanation:</strong> When turning with the arrow (forward), IN1 output high level, IN2 output low level, <strong>red light is on</strong>; when turning against the arrow (reverse), IN1 output low level, IN2 output high level, <strong>green light is on</strong>; when stop turning, the signal output is low level. The output signal is delayed for 60S (the delay time interval can be determined according to the specific requirements of customers)</p>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=0b51c7fbca3396fb5c176c29dc8b406d" alt="" /></p>
<h5>4, CMSV6 Setup and Presention</h5>
<p>After the device is connected to CMSV6, the alarm is triggered, and you can see the forward/reverse/stop status in the platform vehicle information.</p>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=f3737f5c894c05e298e01f5adabd58e7" alt="" /></p>
<p><img src="http://118.195.179.210:9000/server/index.php?s=/api/attachment/visitFile&amp;sign=7cf41ab80bc7cbb28d42eefb183c2864" alt="" /></p>